Energy, mining and utilities
Prove the systems that keep the lights on are secure.
- Remote access to plant systems is controlled Passing
- Critical systems are known and protected Passing
- Contractor access ends with the contract Passing
- Incidents are detected and reported Passing
- Employee and customer data is protected Passing
Evidence saved sha256 d734cf17…393998
Overview
Power producers, grid operators, water utilities, oil and gas companies and mines run control systems where a cyber incident can become a physical one. Many of these systems fall under the Cybersecurity Act as critical information infrastructure, and the same companies hold personal data on large workforces, contractors and customers.
The problem
Control rooms and remote sites run on systems built to last decades, managed by engineers and contractors who rotate in and out. The office network and the plant are more connected every year, and every connection is a way in.
- 01
Old systems, new connections
Operational systems built for isolated sites are now linked to office networks and remote access tools.
- 02
Contractors on rotation
Mines and plants rely on contractors and vendors whose access is rarely removed when the job ends.
- 03
Remote sites, thin teams
A small security team cannot visit every site, so the record of what was checked is thin.
What you have to prove
Five things your auditor, regulator or customers will ask you to show, why each one matters, and the records that answer it.
Proof 01 of 05
Remote access to plant systems is controlled
What you prove
Every remote connection into control and plant systems is individual, protected by multi-factor authentication, approved and logged, including vendor connections.
Why it matters
Remote access is a common way attackers reach operational systems. A vendor account left open after a maintenance visit is an unlocked door to the plant.
Evidence that answers it
- Remote access accounts listed with owners
- Multi-factor authentication on remote access
- Vendor access approved per visit and removed after
- Connection logs kept
Asked by
Proof 02 of 05
Critical systems are known and protected
What you prove
Control systems, networks and the servers that run them are listed, owned, classified and protected to the standard the Authority sets.
Why it matters
Designated critical information infrastructure is audited against the Authority's directives. The inventory tells you, and the auditor, which failure would stop production or supply.
Evidence that answers it
- A critical asset inventory with owners
- Network separation between office and plant
- Vulnerability scans with their dates
- Patch records, or compensating controls where patching is not possible
Asked by
Proof 03 of 05
Contractor access ends with the contract
What you prove
Contractors and vendors have accounts only while they work for you, and those accounts are reviewed and removed on time.
Why it matters
Large sites can have more contractors than employees. Each one who leaves with an active account is a risk to safety, production and personal data.
Evidence that answers it
- Contractor accounts matched against active contracts
- Leavers in HR matched against active accounts
- Quarterly access reviews signed by site managers
- Shared accounts flagged
Asked by
Proof 04 of 05
Incidents are detected and reported
What you prove
Incidents on IT and operational systems are detected, handled and reported to the Authority within the times it sets.
Why it matters
In a plant, a cyber incident can become a safety incident. Reporting lets the Authority and the sector respond before an attack spreads to other operators.
Evidence that answers it
- Monitoring and alerting on IT and plant networks
- Incident records with detection and report times
- A signed incident response and reporting procedure
- Recovery exercises recorded
Asked by
Proof 05 of 05
Employee and customer data is protected
What you prove
Personal data on employees, contractors and customers, such as identity documents, payroll and meter records, is collected for a purpose, secured, and kept no longer than needed.
Why it matters
Act 843 applies to every organisation that processes personal data. Large workforces and customer bases mean large registers, and the Commission expects registration and safeguards to match.
Evidence that answers it
- Current registration with the Data Protection Commission
- A signed data protection policy
- Access to HR and billing systems reviewed
- A retention and disposal policy applied
Asked by
How Afranta helps
-
The Collector for systems inside your network
Active Directory, relational and non-relational databases, Linux hosts and network devices are read from inside your network, and only results leave over an outbound encrypted connection. On Enterprise.
-
Access reviewed every day
Who can reach sensitive data in your identity, HR and cloud tools is checked daily, and leavers who still have access are flagged.
-
Alerts where your people are
When a control fails, whoever owns it hears by email, SMS or WhatsApp, with fix steps written for the tool they use.
-
The Cyber Security Authority can be invited
Examiners from the Cyber Security Authority can be invited to review evidence in the Audit Hub, on every plan.
Evidence you can check
SampleEvery record is saved with a SHA-256 hash. Change one character and the hash no longer matches, so any edit after collection shows.
- Saved hash
- d734cf17692c674d2cc6183cc3b9e9b51346c9edc632c5d9899b021eae393998
- Hash now
- d734cf17692c674d2cc6183cc3b9e9b51346c9edc632c5d9899b021eae393998
Matches. Nothing has changed since it was collected.
Connects to the tools you already run
See every integration- Active Directory
- Microsoft Entra ID
- SAP SuccessFactors
- Workday
- Microsoft Defender
- Wazuh
- Tenable
- Zabbix
- WhatsApp Business
- Hubtel SMS
The frameworks you answer to
Each check is mapped once and counts toward every framework it satisfies.
Other industries
See your own controls checked, live, in a 30-minute demo.
Or email support@afranta.com